• Only US$29.05, buy best aneng an870 auto range digital precision multimeter 19999 counts true-rms ncv ohmmeter ac/dc voltage ammeter transistor tester sale online store at wholesale price.
  • Buy ANENG A830L Handheld Multimeter Voltage Meter Household Electrical Instrument at cheap price online, with Youtube reviews and FAQs, we generally offer free shipping to Europe, US, Latin America, Russia, etc.
  • A830L Digital Multimeter is a pocket-size electronic measuring instrument that combines most commonly-used measurement functions in one unit, with test functions for voltage, current, resistance, continuity, diodes, and transistor hFE.
  1. Aneng Multimeter A830l User Manual Download Windows 10
  2. Aneng An8002 User Manual

1. User Manual. Multi Meter Test Pen can be sold separately. Buy only multimeter pen included. A830l multimeter. Buy ANENG AN888S BT Audio Multimeter Multifunction Digital Display Voltage Current Meter 19999 Counts High Precision Automatic Range Desktop Universal Meter with Test Probe Kit online on Amazon.ae at best prices. Fast and free shipping free returns cash on delivery available on eligible purchase. In the video I take a look at a really cheap Aneng A830L digital multimeter to find out if it even works. And surprisingly it does to some degree and it's q.

Download or browse on-line these Operation & User’s Manual for Aneng Q1 Multimeter.

Aneng Q1 Manual Information:

This manual for Aneng Q1, given in the PDF format, is available for free online viewing and download without logging on. The guide contains 26 pages, and the size of the file at download is . The document type is Operation & User’s Manual.

Summary of Contents

[Page 1] Aneng Q1 Manual

All rights reserved. Specifications are subject to change without notice. User Manual ..

[Page 2] Aneng Q1 Manual

LIMITED WARRANTY AND LIMITATION OF LIABILITY Customers enjoy one-year warranty from the date of purchase. This warranty does not cover fuses, disposable batteries, damage from misuse accident, neglect, alteration, contamination, or abnormal conditio..

[Page 3] Aneng Q1 Manual

Table of Contents Page Introduction.............................1 Safety Information........................1 Instrument Overview.....................

[Page 4] Aneng Q1 Manual

Maintenance............................15 Clean the Product.....................15 Replace the Batteries..................15 Replace the Fuses....................16 Sp..

[Page 5] Aneng Q1 Manual

Introduction This product is a 9999 counts true RMS auto- ranging digital multimeter. It is operated all by buttons with a triple display. Safety Information To avoid possible electrical shock, fire, or personal injury, please read all safety informa..

[Page 6] Aneng Q1 Manual

• Keep fingers behind the finger guards on the probes. • When the product has already been connected to the line being measured, do NOT touch the input terminal that is not in service. • Disconnect the test leads from the circuit before changin..

[Page 7] Aneng Q1 Manual

3 LCD Display ① Auto range. The product selects the range with the best resolution. ② Manual range. The user selects the range. ③ Display shows maximum reading. ④ Relative mode. ⑤ Diode test. ⑥ Continuity test. ⑦ Displ..

[Page 8] Aneng Q1 Manual

4 ⑪ Frequency test. (Hertz) ⑫ Temperature test. (Celsius) ⑬ Temperature test. (Fahrenheit) ⑭ Analog bar graph. ⑮ Resistance test. (Ohm) ⑯ Current test. (Ampere) ⑰ Voltage test. (Volt) ⑱ Primary measurement disp..

[Page 9] Aneng Q1 Manual

5 Function Buttons ① ② ③ ④ ⑤ ⑥ ⑦ ① Push for more than 2 seconds to turn on/off the product. • The product automatically powers off after 5 minutes of inactivity. • The built-in beeper beeps 5 times 1 minute before auto p..

[Page 10] Aneng Q1 Manual

6 ② Push once to hold the current reading on the display ; push again to continue normal operation . Push for more than 2 seconds to enter the relative mode. The product will store the present reading as a reference for subsequent rea..

[Page 11] Aneng Q1 Manual

⑦ Push this button when the product is at the setting of ACV, the primary measurement display will show the current frequency (1 ~100kHz) while the secondary measurement display will show the current duty cycle. Push this button when th..

[Page 12] Aneng Q1 Manual

Input Terminals 8 A mA Input terminal for AC/DC current measurements to 9.999A. μA Input terminal for AC/DC current measurements to 999.9μA. COM Common (return) terminal for all measurements . VΩHz Input terminal for the measurements..

[Page 13] Aneng Q1 Manual

9 Measurements Instruction Measure AC/DC Voltage 1. Connect the black test lead to the COM Terminal and the red lead to the VΩHz Terminal. 2. To measure voltage under 99.99mV, push , push once to measure DCmV, push twice to measure ACmV. To measure ..

[Page 14] Aneng Q1 Manual

10 2. Push to toggle between DCA and ACA. 3. Break the circuit path to be measured, connect the test leads across the break and apply power. 4. Read the measured current on the display. Measure Resistance 1. Connect the black test lead to the COM Ter..

[Page 15] Aneng Q1 Manual

11 Test Diodes and Continuity 1. Connect the black test lead to the COM Terminal and the red lead to the VΩHz Terminal. 2. Push twice to enter the Diode/Continuity Mode. 3. To test continuity, touch the probes to the desired test points of the circu..

[Page 16] Aneng Q1 Manual

2. Push three times to enter the Capacitance Mode. 3. Connect the red probe to the anode side and the black probe to the cathode side of the capacitor being tested. 4. Read the measured capacitance value on the display once the reading is stablized. ..

[Page 17] Aneng Q1 Manual

3. When the frequency to be measured is between 100kHz and 500MHz, push twice to enter the ACmV Mode; touch the probes to the desired test points, and the secondary measurement display will show the frequency; then push , the primary measurement disp..

[Page 18] Aneng Q1 Manual

14 2. Touch the probes to the desired test points. 3. Read the measured temperature on the display. Test NCV 1. Push twice to enter the NCV Mode. 2. Hold the product and move it around, the built- in beeper will beep when the inner sensor detects AC ..

[Page 19] Aneng Q1 Manual

Maintenance Beyond replacing batteries and fuses, do not attempt to repair or service the product unless you are qualified to do so and have the relevant calibration, performance test, and service instructions. Clean the Product Wipe the product with..

[Page 20] Aneng Q1 Manual

2. Loosen the screw on the battery door and remove the battery door. 3. Replace the used batteries with new batteries of the same type. 4. Place the battery door back and fasten the screw. Replace the Fuses When a fuse is blown or do not work properl..

[Page 21] Aneng Q1 Manual

Specifications 17 General Specifications Display (LCD) 9999 Counts Ranging Auto/Manual Material ABS+TPE Update Rate 3 Times/Second Ture RMS √ Data Hold √ Backlight √ Low Battery Indication √ Auto Power Off √ Mechanical..

[Page 22] Aneng Q1 Manual

Electrical Specifications 18 Function Range Resolution Accuracy DC Voltage (V) 999.9mV 0.1mV ±(0.5%+3) 9.999V 0.001V 99.99V 0.01V 999.9V 0.1V DC Voltage (mV) 9.999mV 0.001mV 99.99mV 0.01mV AC Voltage (V) 999.9mV 0.1..

[Page 23] Aneng Q1 Manual

19 Function Range Resolution Accuracy DC Current (mA&A) 999.9mA 0.1mA ±(1.0%+3) 9.999A 0.001A DC Current (μA) 99.99μA 0.01μA ±(0.8%+3) 999.9μA 0.1μA AC Current (mA&A) 999.9mA 0.1mA ±(1.2%+3) 9.999A 0.001A AC..

[Page 24] Aneng Q1 Manual

Function Range Resolution Accuracy Capacitance 9.999nF 0.001nF ±(5.0%+20) 99.99nF 0.01nF ±(2.0%+5) 999.9nF 0.1nF 9.999μF 0.001μF 99.99μF 0.01μF 999.9μF 0.1μF 9.999mF 0.001mF ±(5.0%+5) Frequency (Measures only to 100kH..

[Page 25] Aneng Q1 Manual

21 Function Range Resolution Accuracy Temperature ( -20~1000) ℃ 1 ℃ ± (2.5%+5 ) ( -4~1832)℉ 1 ℉ Diode √ Continuity √ NCV √ ..

[Page 26] Aneng Q1 Manual

..

Related Devices for Aneng Q1

Related Manuals for Aneng Q1

The Digital Multimeter is a practical tool for electrician use. It is easy to operate and the readings indicated directly on the screen. It can be use to overhaul all kinds of circuit boards. It is also an ideal teaching instrument for students.

This multi meter has been designed according to IEC -1010 concerning electronic measuring instruments with a overvoltage category (CAT n) and pollution 2.Follow all safety and operating instructions to ensure that the meter is used safely and is kept in good operating condition. Full complianca with safety standards can be guaranteed only with test leads supplied. If necessary, they must be replaced with the type specified in this manual.

Aliexpress.com

If you need my experiences with this type multimeter or how calibrate voltage on multimeter please read my review

SAFETY SYMBOLS

MAINTENANCE OF MULTIMETER XL830L

• Before opening the case, always disconnect test leads from all energized circuits.

• For continue protection against fire: replace fuse only with the specified voltage and current ratings :

F 200mA/250V(Ouick Acting)

• Never use the meter unless the back cover is in place and fastened completely.

• Do not use abrasives or solvents on the meter. To clean It using a damp cloth and mild detergent only.

DURING USE

• Never exceed the protection limit values indicated in specifications for each range of measurement

• When the meter is linked to measurement circuit, do not touch unused terminals .

• Never use the meter to measure voltages that might exceed 600V above earth ground in category II installations.

• When the value sclae to be measured is unkonwn beforehand, set the range selector at the highest position .

• Before rotating the range selector to change functions ,disconnect test leads from the circuit under test.

• When carrying out measurements on TV or switching p·lwer circuits always remember that there may be high amplitude voltages pulses at test points. which can damage the meter.

• Always is careful when working w1th voltages above 60V dc or 30V ac rms . Keep fingers behind the probe barriers while measuring.

• Before attempting to insert transistors for testing. always be sure tlat test leads have been disconnected from any measurement circuits.

• Components should not be connected to the hFE socket when making voltage measurements with test leads.

• Never perform resistance measurements on live circuits .

GENERAL DESCRIPTION OF XL830L MULTIMETER

Ranges – Acurracy of Multimeter XL830L and operation instructions

DC VOLTAGE MEASUREMENT

1. Connect the red test lead to the ” V.Q.mA” jack· and the black lead to the “COM ” jack.

2. Set rotary switch at desired DCV position, If the voltage to be measured is not known beforehand , set range switch at the highest range position and then reduce ituntil satisfactory resolution is obtained.

3. Connect test leads across the source or load being measured.

4 . Read voltage value on the LCD display along with thepolarity of the red lead connection.

CURRENT MEASUREMENT

1. Connectthe red test lead to the “V.Q.mA” jack and theblack test lead to ” COM ” jaCk. (For measurements between 200mA and lOA, remove red lead to “10 A” jack.)

2. Set the rotary switch at’ desired DCA position.

3. Open the circuit in which the current is to be measured .and connect test leads in series with the circuit

4. Read .current value on LCD display along with the polarity of red lead connection .

AC VOLTAGE MEASUREMENT

1. Connect the red test lead to ” V.Q.mA” jack and the black test lead to the ” COM ” jack.

2. Set the rotary switch at desired ACV position.

3. Connect test leads across the source or load being measured.

4. Read voltage value on the LCD display.

RESISTANCE MEASUREMENT

1. Connect the red test lead to “V.Q.mA” jack and black test lead to the ” COM ” jack. (The polarity of red lead ispositive ” +” . )

2. Set the rotary switch at desired ” !l” range position.

3. Connect test leads across the resistor to be measured and read LCD display.

4. If the res istance being measured is connected to a circuit, turn off power and discharge all capacitors before applying test probes.

DIODE TEST

TRANSISTOR TEST

1. Set the rotary switch at ” hFE ” position.

2. Delermine whether the transistor under testing is NPN or PNP and locate the emitter, base and collector leads.

Insert the leads into proper holes of the hFE socket on the front panel.

Aneng Multimeter A830l User Manual Download Windows 10

3. Read the approximate hFE value at the test condition of base current 10 μA and Vce 3V.

NOTE: To avoid electrical shock, remove test leads from measurement circuits before testing a transistor.

BATTERY & FUSE REPLACEMENT

Fuse rarely need replacement and blow almost always as a result of operator’s error.

To replace battery & fuse {200mAI250V) remove the 2 screws in the bottom of the case. Simply remove the old, and replace with a new one.Be careful to observe battery polatity.

WARNING!!!

Before attempting to open the case, always be sure that test leads have been disconnected from measurement circuits.

Close case and tighten screws completely before using the meter to avoid electrical shock hazard.

STANDARD ACCESSORIES

• Operator’s instruction manual

• Set of test leads

• Gift box

• 9 volt battery. NEDA 1604 6F22 006P type

• Holster (option)

Multimeter technical features and parameters

  • 100% brand new and high quality .

  • The Digital Multimeter is a practical tool for electrician use. /pes-2019-crack.html. It is easy to operate and the readings indicated directly on the screen. It can be use to overhaul all kinds of circuit boards. It is also an ideal teaching instrument for students.

  • 15mm high LCD Display

  • Portable and compact design, overload protection on all ranges

  • Diode assembly test/Transistor P-N junction test/Transistor HFE test

  • Continuity test with buzzer sound in circuit.

  • Low battery voltage indication

Specification of ranges and accuracy:

  • DC Voltage: 200mV/2V/20V/200V +- 0.5%, 600V +- 0.8%

  • AC Voltage: 200V/600V +- 1.2%

  • DC Current: 200¦ÌA/2mA/20mA +- 1%, 200mA +- 1.5%, 10A +- 3%

  • Resistance: 200¦Ø/2K¦Ø/20K¦Ø/200K¦Ø/2M¦Ø +- 0.8%

  • /kingdom-come-deliverance-xbox-one-digital-code-free-download.html. Display: LCD, 1999 counts

  • Fuse protection: F-200mA/250V

  • Operating Temperature: -0C to 40C

  • Overrange Indication: Only figure “1” on the display

  • Polarity Indication: “-” displayed for negative polarity

  • Low Battery Indication: – /+ display

  • Power by: 9V Battery(Not included)